"tone" Module: Tone Definition Settings

The Tone Definition settings configure data for various tones for the purpose of localization.
The Audio Manager component uses the data from this model to populate the mcu on
bootup.
Each tone definition must be a string of 12 elements separated by a space:
"<num of freq> <freq1> <amp1> <freq2> <amp2> <freq3> <amp3> <freq4> <amp4>
<on duration> <off duration> <repeat count>"
Where:
<num of freq>: 0-4
<freq1>: 0-65535
<amp1>: -32768-32767
<freq2>: 0-65535
<amp2>: -32768-32767
<freq3>: 0-65535
<amp3>: -32768-32767
<freq4>: 0-65535
<amp4>: -32768-32767
<on duration>: 0-2^32
<off duration>: 0-2^32
<repeat count>: 0-65535
All the tone definition settings are included in the general configuration file.
Setting:
Description:
Values:
Setting:
Description:
Values:
Configuration File Parameter Guide
M100 KLE Administrator and Provisioning Manual
tone.inside_dial_tone.num_of_elements
Sets the number of tone elements for the dial tone.
1–5
tone.inside_dial_tone.element.1
Defines the inside dial tone element 1.
Tone element string
174
Default:
1
Default:
2 440 -22 350 -22 0 0 0 0
65535 0 65535