INPutn:DEBounce:TIME? [MINimum | MAXimum | DEFault]

Returns the current debounce time for Port n as a floating point number
formatted as +d.ddddddE±ddd
Parameters
Parameter Name
INPutn
<time>
DEFault
MINimum
MAXimum
Comments
Example
52
– *RST Condition: sets the value for the debounce time to 18.0Sec for all
four Ports.
Parameter Type
numeric
numeric (floating pt)
– Ports 0 and 1 use the same debounce time, Ports 2 and 3 use the same
debounce time. For n = 0 or n = 1, this command returns the debounce
time for both Ports 0 and 1; for n = 2 or n = 3, this command returns the
debounce time for both Ports both Ports 2 and 3.
INP2:DEB:TIME?
Queries input circuit debounce time of Port 2
Range of Values
0, 1, 2, 3
18.0 sec through 9600 sec
Default 18.0 sec
Minimum 18.0 sec
Maximum 9600 sec
Keysight E1459A/Z2404B User and SCPI Programming Guide
DISPlay:MONitor Subsystem
Default
0
18.0
sec