SYSTem Subsystem
SYSTem Subsystem
The SYSTem Subsystem returns module-specific information. This information
includes module type and description, and error messages.
Syntax
SYSTem
SYSTem:CDEScription? <number>
Returns the module description.
Parameters
Comments
Example
Keysight E1459A/Z2404B User and SCPI Programming Guide
:CDEScription? <number>
:CTYPe? <number>
:ERRor?
:VERsion?
Parameter Name
Parameter Type
<number>
– <number> must be equal to 1 since only one Keysight E1459A module is
allowed in a single instrument (logical address).
– The command returns the following string:
"64-Channel Isolated Digital Input / Interrupt"
SYSTem:CDEScription? 1
Range of Values
Numeric
Requests the module description.
Keysight E1459A SCPI Command Reference
1
Default
None
73