System:ctype? <Number; System:error - Keysight E1459A User & Scpi Programming Manual

64-channel isolated input interrupt module
Table of Contents

Advertisement

Keysight E1459A SCPI Command Reference
SYSTem:CTYPe? <number>
Returns the module card type.
Parameters
Parameter Name
Comments
Example

SYSTem:ERRor?

Queries the error register for the error value and string to identify the error. The
errors are held in an error buffer and read on a First-In-First-Out basis.
Parameters
Comments
Example
SYST:ERR?
74
Parameter Type
<number>
Numeric
– <number> must be equal to 1 since only one Keysight E1459A module is
allowed in a single instrument (logical address).
– The command returns the following string:
"HEWLETT-PACKARD,E1459A/Z2404B,0,revision"
(revision is the revision of the driver, for example A.01.00).
SYSTem:CTYPe?
None
– Returns the error number and string. If no errors are in the error buffer, the
command returns:
+0,"No error"
– *CLS clears the error buffer.
– *RST does not affect the error buffer
– Refer to Appendix C for possible error messages.
Range of Values
Requests the module card type.
Requests the error messages.
Keysight E1459A/Z2404B User and SCPI Programming Guide
SYSTem Subsystem
Default
1
None