Input Data Capture - Keysight E1459A User & Scpi Programming Manual

64-channel isolated input interrupt module
Table of Contents

Advertisement

Functional Description

Input Data Capture

The state of any channel, within any channel group, may be captured for
subsequent processing (as data) by an externally sourced capture clock
(XTRIG0N - XTRIG3N, the external trigger inputs for each port). Data channels
may be interspersed among all 64 channel inputs, but the user is cautioned to
ensure that all setup criteria and clock sources coincide with requirements for
synchronization. (Each channel group shares a common capture clock which may
not necessarily be synchronous with an external capture clock of some other
channel group.)
If enabled, each register FPGA will post a "Data Available Marker" to the control
FPGA on the occurrence of a corresponding capture clock. Data Available
Markers are cleared by a read of the corresponding "Channel Data Register."
(The static state of these markers may be tested via the "Data Available
Register.") Capture clocks which occur concurrently with a "register read/marker
clear" cycle, are queued and post- processed on completion of the present cycle.
In that event, the marker bit is forced inactive for a two clock (16 MHz) period
before again being posted to the control FPGA.
In the "Data Capture Mode", the Keysight E1459A may be programmed to
generate an interrupt on the occurrence of an external capture clock, or an
internal 1.0 MHz sample clock may be selected to allow the state of the data
channels to be tested in the absence of a capture clock. Capture clock selection
(internal/external) is controlled by bit 1 of the Command Register Word.
Keysight E1459A/Z2404B User and SCPI Programming Guide
A potential hazard exists if software were to improperly program
the Keysight E1459A to post data-capture IRQ's with the
internally selected 1.0 MHz clock source. In this situation, a DAV
interrupt would be posted each microsecond (if software were
able to service at that rate), and would cause software to
continuously vector to interrupt service upon each "return from
service." Therefore, the Keysight E1459A should never be
programmed to generate DAV interrupts with the internal clock
source selected.
In the Keysight E1459A the Data Ready Marker is guaranteed to
be cleared when the clock source is switched from internal to
external. Therefore, any capture clock which occurs within the
internal/external clock selection interval will not post a marker to
the control FPGA and will be lost.