Perform Error-Free Verification Test (Copy 1) - Alcatel-Lucent 1677 SONET Link Manual

Turn-up
Hide thumbs Also See for 1677 SONET Link:
Table of Contents

Advertisement

3EM13850AD
Issue 01, September 2007
DLP-129

Perform Error-Free Verification Test (Copy 1)

PURPOSE
The purpose of this procedure is to force all traffic to the copy 1 SSC and perform an error-free
verification test with all traffic on the copy 1 SSC.
PREREQUISITES
The test environment established in
GENERAL
For information on TL1 command syntax, refer to the 1677 SONET Link Commands and Messages
manual (PN 3EM13852AF).
Refer to the 1677 SONET Link Address and Location Guide (PN 3EM13854AD) for module
locations.
This procedure makes reference to S and SS, where S=slot number and SS=subslot number in shelf.
Use
CKL-119
for this procedure.
STEP
PROCEDURE
Reseat copy 1 SSC.
1
Enter
2
RST-EQPT::SWC-8;
noticed due to matrix switch.)
Enter
3
Do alarms exist?
4
Clear all alarms that prevent testing, then go to step 6. Refer to 1677 SONET Link
5
Maintenance and Trouble Clearing manual (PN 3EM13853AF).
Enter
6
Do conditions exist that prevent testing?
7
Perform Error-Free Verification Test (Copy 1)
DLP-120
to logically restore copy 1 SSC in slot 8. (Some errors may be
to verify there are no alarms present to prevent testing.
RTRV-ALM-ALL;
If yes, go to step 5.
If no, verify in CKL-119, then go to step 6.
to verify there are no conditions present to prevent testing.
RTRV-COND-ALL;
If yes, go to step 8.
If no, verify in CKL-119, then go to step 9.
and
DLP-121
must be intact.
DLP-129
4-187