Activate Mos Module; Dlp-134 Activate Mos Module - Alcatel-Lucent 1677 SONET Link Manual

Turn-up
Hide thumbs Also See for 1677 SONET Link:
Table of Contents

Advertisement

3EM13850AD
Issue 01, September 2007
DLP-134

Activate MOS Module

PURPOSE
This procedure is used to activate a MOS module.
GENERAL
Use this procedure for initial turn-up of a system only. Never use this procedure on a traffic-carrying
system. When working with a traffic-carrying system, refer to the 1677 SONET Link Maintenance
and Trouble Clearing manual (PN 3EM13853AC).
There is no checklist for this procedure.
STEP
PROCEDURE
Enter
1
is placed in service.
Examine output to determine if MOS modules have been placed in service.
2
Enter
3
reported until MOS is forced in service.
The following output is representative of typical successful response:
cr lf lf
^^^<SID>^<YY-MM-DD>^<HH:MM:SS> cr lf
M^^<CTAG>^COMPLD cr lf
^^^/* <RST-EQPT::MOS> */ cr lf
;
Enter
4
modules in service.
If the command is issued with FRCD mode, the system discovers the modules on the
OMB, and the database is updated. This can possibly take several minutes. In NORM
mode, the system discovers the modules and displays the contents only.
Activate MOS Module
to retrieve status of MOS. No devices are found until MOS module
RTRV-MOS;
to place MOS module in service. Various alarms may be
RST-EQPT::MOS;
to force system to locate MOS modules and place the
RTRV-MOS:::::FRCD;
DLP-134
4-209