Alcatel-Lucent 1677 SONET Link Manual page 232

Turn-up
Hide thumbs Also See for 1677 SONET Link:
Table of Contents

Advertisement

DLP-129
Clear all alarms and conditions that prevent testing, then go to step 9. Refer to
8
1677 SONET Link Maintenance and Trouble Clearing manual (PN 3EM13853AF).
Enter
9
configuration, is reported for CURREFSRC.
Is EXTERNALA or LINEA reported for CURREFSRC?
10
Enter
11
Go to step 9.
12
Enter
13
Unseat SSC in slot 7.
14
Enter
15
Does SSC in slot 7 indicate IS and WRK?
16
Refer to 1677 SONET Link Maintenance and Trouble Clearing manual
17
(PN 3EM13853AF) to clear trouble.
Is trouble cleared?
18
Are errors reported?
19
Refer to 1677 SONET Link Maintenance and Trouble Clearing manual
20
(PN 3EM13853AF) to determine source of error before going to next step.
Reset test set error count to zero.
21
Monitor test set(s) for 15 minutes for error-free verification.
22
4-188
to verify EXTERNALA or LINEA, depending on timing
RTRV-SYNCN;
If yes, record information in CKL-119, then go to step 13.
If no, go to step 11.
to switch CURREFSRC to EXTERNALA or LINEA.
OPR-SYNCNSW;
to logically remove copy 0 SSC in slot 7.
RMV-EQPT::SWC-7;
RTRV-STATE-EQPT::SWC-7;
If yes, go to step 19.
If no, go to step 17.
If yes, go to step 15.
If no, go to step 17.
If yes, go to step 20.
If no, record information in CKL-119, then go to step 21.
to retrieve state of active SSC in slot 7.
Perform Error-Free Verification Test (Copy 1)
3EM13850AD
Issue 01, September 2007

Advertisement

Table of Contents
loading

Table of Contents