Alcatel-Lucent 1677 SONET Link Manual page 246

Turn-up
Hide thumbs Also See for 1677 SONET Link:
Table of Contents

Advertisement

DLP-131
Have all OC-ns on protect OCn module been switched to back to working?
18
Enter
19
RMV-EQPT::AID;
by switching all facilities back to working.
where: AID=STBYH OCn module AID
Reset test set error count to zero and monitor for 10 seconds.
20
Does test set indicate that no errors occurred during monitoring period?
21
Refer to 1677 SONET Link Maintenance and Trouble Clearing manual
22
(PN 3EM13853AF) to clear trouble.
Is trouble cleared?
23
Enter
24
where: AID=protecting OCn module AID
Enter
25
protect OCn module.
where:
n=3, 12, 48, or 192
AID=protecting OC-n facility AID
Have all facilities on protect OCn module been released from protection switch?
26
Have all OCn module mated pairs been tested?
27
Reseat copy 0 SSC.
28
4-202
If yes, record verification in CKL-121, then go to step 19.
If no, go to step
to logically remove protect OCn module that was made STBYH
If yes, go to step 24.
If no, go to step 22.
If yes, go to step 24.
If no, go to step 22.
to restore protecting OCn module to in-service (IS) status.
RST-EQPT::AID;
RLS-PROTNSW-OCn::AID;
If yes, go to step 27.
If no, go to step 25.
If yes, go to step 28.
If no, go to step
module mated pair.
11
to switch next OC-n back to working.
to release protection switch for first OC-n facility on
11
to perform protect-to-working switching on next OCn
Verify OC-n Protection Switching (Protect to Working)
3EM13850AD
Issue 01, September 2007