Alcatel-Lucent 1677 SONET Link Manual page 211

Turn-up
Hide thumbs Also See for 1677 SONET Link:
Table of Contents

Advertisement

3EM13850AD
Issue 01, September 2007
Reset test set error count to zero and monitor for 10 seconds.
315
Are errors reported?
316
Enter
317
Are SYNCSEC alarms present against TC-11-A and TC-11-B?
318
Refer to 1677 SONET Link Maintenance and Trouble Clearing manual
319
(PN 3EM13853AF) or contact next level of support to resolve problem. Do not proceed
with procedure until problem is resolved. Go to step 317.
Is a BITS clock splitter being used?
320
Reconnect timing source at B IN on front panel of TCs in slots 11A and 11B. Refer to
321
1677 SONET Link Engineering Support Documentation (PN 3EM17362AD) and see
drawing 3EM171590004RJZZA for information.
Go to step 324.
322
Reconnect BITS-1 source to BITS clock splitter at J502 connector.
323
Are errors reported?
324
Refer to 1677 SONET Link Maintenance and Trouble Clearing manual
325
(PN 3EM13853AF) to determine source of error before going to next step.
Reset test set error count to zero and monitor for 10 seconds.
326
Are errors reported?
327
Enter
328
Verify Clock and Control Subsystem Switching
If yes, go to step 314.
If no, record information in CKL-115, go to step 323.
RTRV-ALM-ALL;
If yes, go to step 323.
If no, go to step 319.
If yes, go to step 323.
If no, go to step 321.
If yes, go to step 325.
If no, record information in CKL-115, then go to step 328.
If yes, go to step 325.
If no, record information in CKL-115, go to step 328.
RTRV-ALM-ALL::ALL;
DLP-125
4-167