DLP-125
Enter
62
Observe output. Note states of disks in CCC in slot 9.
63
Is state of disks in CCC in slot 9 OOS-MA?
64
Enter
65
secondary.
Enter
66
secondary.
Did output return COMPLD or DENY?
67
Enter
68
Observe output. Note states of disks in CCC in slot 9.
69
Verify PST=OOS-AUMA and SST=SWDL. While secondary disk synchronizes, a
70
BKUPMEMSYNCH condition exists. Wait until BKUPMEMSYNCH condition clears
before continuing.
Are there errors?
71
Refer to 1677 SONET Link Maintenance and Trouble Clearing manual
72
(PN 3EM13853AF) to resolve problem, then go to step 73.
Is problem resolved?
73
Reset test set error count to zero and monitor for 10 seconds.
74
Verify that no errors are observed on test set.
75
4-148
to check state of disks.
RTRV-DISK;
If yes, go to step 65.
If no, go to step 333.
ACT-DISK::DISK-A9::::MODE=SEC,ACTION=ACTIVATE;
ACT-DISK::DISK-B9::::MODE=SEC,ACTION=ACTIVATE;
If COMPLD, go to step 68.
If DENY, go to step 333.
RTRV-DISK;
If yes, go to step 72.
If no, go to step 77.
If yes, go to step 74.
If no, go to step 72.
Issue 01, September 2007
to activate disk A9 as
to activate disk B9 as