Figure 103-2. Ccc Front Panel - Alcatel-Lucent 1677 SONET Link Manual

Turn-up
Hide thumbs Also See for 1677 SONET Link:
Table of Contents

Advertisement

3EM13850AD
Issue 01, September 2007
Interlock switch
No critical alarms.
Active critical alarm.
No major alarms.
Active major alarm.
No minor alarms.
Active minor alarm.
Visual-alarm
terminal block
Audible-alarm
terminal block
DIAG
CCC diagnostic port
(for factory use only)
1
2
3
4
5
6
7
8
9
B
A
Card-cage slot location
Install Plug-In Modules

Figure 103-2. CCC Front Panel

Off
CR
Red
RUN
PRI.
Off
MJ
HEALTH
Red
IN-USE
Off
MN
CR
PWRA
Amber
MJ
PWRB
MN
FAN
ALARMS
ACO/LMPTST
VISUAL
+
CR
-
+
MJ
-
+
-
MN
CR
+
-
+
MJ
-
+
-
MN
AUDIBLE
DIAG
Disk B
Disk A
10
11 12 13 14 15 16 17
B
DISK B
DISK A
A
TO
MOS
Run
Off
Green
Flashing The CCC is running diagnostics or
PRI.
Green
Amber
Health
Green
Amber
Red
In Use
Off
Green
PWRA
Green
Red
PWRB
Green
Red
Fan
Green
Amber
Red
ACO/LMPTST
Flash-disk
access cover
To
modular optical system
(One-wire cable port)
The CCC is not running.
The CCC is running.
loading code.
This is the primary (active) CCC.
This is the secondary (standby) CCC.
The module is operating and has no
detected faults.
The module has a minor fault.
The module is not operating. It has a
hardware fault.
Interlock switch pushed to the right.
Module can be removed.
Module is executing operating code.
Do not remove module.
Power source A on.
Power source A not connected, off,
or failed.
Power source B on.
Power source B not connected, off,
or failed.
All fans running.
One fan failure. Replace fan-tray
module as soon as possible to
avoid system thermal failure.
Two or more fan failures. Replace
fan-tray module immediately.
Press the Alarm Cut-Off/Lamp Test
(ACO/LMPTST) switch to shut off the
current audible alarm. To test all LEDs
on all modules in the system, press
and hold the ACO/LMPTST switch
for 5 seconds.
DLP-103
677-0007-1
110904
4-11