DLP-121
(2) SC-SC Single Mode (SM) optic cable
(1) Dual SC-MTRJ Single Mode (SM) optic cable
(1) SC-SC dual optic coupler
Single Mode and SC-to-SC looping plugs
Single Mode FC-to-SC jumper cables
(2) Attenuators, as appropriate for test set and power level of GIGE or OCn module output
(2) 10 dBm attenuators
(2) 15 dBm attenuators
STEP
PROCEDURE
Enter
1
Do alarms exist that prevent testing?
2
Clear all alarms that prevent testing, then go to step 4. Refer to 1677 SONET Link
3
Maintenance and Trouble Clearing manual (PN 3EM13853AF).
Enter
4
Do conditions exist that prevent testing?
5
Clear all conditions that prevent testing, then go to step 10. Refer to
6
1677 SONET Link Maintenance and Trouble Clearing manual (PN 3EM13853AF).
Is shelf equipped with GIGE modules?
7
4-100
to verify there are no alarms present to prevent testing.
RTRV-ALM-ALL;
If yes, go to step 3.
If no, go to step 4.
to verify there are no conditions present to prevent testing.
RTRV-COND-ALL;
If yes, go to step 6.
If no, go to step 7.
If yes, go to step 8.
If no, go to step 9.
Set Up GIGE and OCn Modules for Error-Free Verification Tests
3EM13850AD
Issue 01, September 2007