3EM13850AD
Issue 01, September 2007
Set power meter wavelength to 1310 nm for IR OC3, IR OC12, and SR/IR/LR OC48
11
modules, or set power meter wavelength to 1550 nm for XLR OC48 modules. Refer to
table
116-A
Information manual (PN 3EM13848AF) for wavelength information by part number
for XLR OC48 modules and LR OC192 modules.
Measure output optical signal. Refer to table
12
Is power level within minimum and maximum specifications in table 116-A?
13
Clean fiber-optics and optical connectors (refer to DLP-117), and then retest
14
connection. If connection still fails test, recheck fiber-optic cable routing, replace
faulty fiber-optic cable, or replace OCn module.
Go to step
15
Disconnect optical power meter (and attenuator, if applicable) from fiber-optic cable.
16
For fiber-optic cable disconnected from power meter in step 16, reconnect fiber-optic
17
cable at LGX panel.
Connect fiber-optic cable that runs between Rx port of OCn module and LGX panel to
18
Rx port of OCn module under test. SC fiber-optic cables connect to OC12, OC48, or
OC192 modules, and LC fiber-optic cables connect to OC3 module.
On front side of LGX panel, connect fiber-optic jumper to ports corresponding to fiber-
19
optic cables from Tx and Rx port on OCn module under test, using appropriate jumper
for connector types.
Enter
20
jumpered in step 16.
where:
n=3, 12, 48, or 192
AID=access identifier of OC-n.
Is LOS set against OCn?
21
For connection between Rx port of OCn module and LGX panel, clean fiber-optics and
22
optical connectors (refer to DLP-117), and then retest connection. If connection still
fails test, recheck fiber-optic cable routing, replace faulty fiber-optic cable, or replace
OCn module.
Confirm Cabling Between Client-Side I/O and Customer LGX Panel (OCn-Equipped Shelf)
for OCn module specifications. Refer to the 1677 SONET Link Product
If yes, record results in CKL-108, then go to step 16.
If no, go to step 14.
12
to retest connection.
RTRV-COND-OCn::AID:::LOS;
If yes, go to step 22.
If no, go to step 24.
116-A
for OCn module specifications.
for OC-n port for which fiber-optic cables were
DLP-116