Alcatel-Lucent 1677 SONET Link Manual page 102

Turn-up
Hide thumbs Also See for 1677 SONET Link:
Table of Contents

Advertisement

DLP-115
Verify DS3 provisioned in CKL-107.
5
Go to step 9.
6
Enter
7
ENT-EC1::AID;
for provisioning order.
where:
AID=EC1 facility AID
Verify EC1 provisioned in CKL-107.
8
Measure DS3/EC1 Connector Panel Output Across Coaxial Cable at DSX Panel End
Connect test set to front side of DSX panel corresponding to cable from TX port of ECC
9
module under test.
Verify that a valid DS3/EC1 signal is present.
10
Is a valid DS3/EC1 signal present?
11
Recheck coaxial cable routing, and then retest connection. If connection still fails test,
12
replace faulty coaxial cable, replace ECC module, or replace 48-port DS3/EC1
connector panel.
Go to step
13
Disconnect test set from DSX panel.
14
On front side of DSX panel, connect coaxial jumper to ports corresponding to cables
15
from Tx and Rx port on ECC under test.
Is ECC port under test provisioned with DS3 or EC1?
16
Enter
17
RTRV-COND-T3::AID:::LOS;
step 15.
where:
AID=access identifier of DS3.
Go to step 20.
18
4-58
to provision one EC1 on working ECC module. Refer to
If yes, record results in CKL-106, then go to step 14.
If no, go to step 12.
10
to retest connection.
If DS3, go to step 17.
If EC1, go to step 19.
Confirm Cabling Between Client-Side I/O and Customer DSX Panel (ECC-Equipped Shelf)
for T3 port for which coaxial cables were jumpered in
3EM13850AD
Issue 01, September 2007
CKL-107