DLP-103
Press
29
Enter
Various messages display. On successful reboot, system responds with the following:
INITIALIZING SYSTEM MANAGER...
STARTUP COMPLETE.
PCM file load complete: CLI, TL1 and Snmpd enabled
NOTICE: This is a private computer system.
Unauthorized access may lead to prosecution.
Username:
Remove laptop or VDT and CCC interface cable connected to DIAG port on CCC.
30
Go to step 44.
31
DS0G and OC192-1Ps are full-height modules. Slot separator between A and B slot
32
halves must be removed before module can be inserted into slot.
Using 8-inch Phillips screwdriver, remove single screw holding slot separator between
A and B slot halves on shelf.
Go to step 37.
33
TCs are keyed to correctly install only into slots 11A and 11B.
34
Go to step 37.
35
EDFAs are double-width modules. Card separator between adjoining slots must be
36
removed before module can be inserted into double-width slot.
Using 8-inch Phillips screwdriver, remove card separator between adjoining slots.
WARNING: Possibility of equipment damage. Do not force module into slot or
37
connectors.
To install modules, use following procedure:
38
a.
Check slot and connectors for any obstacles or bent connectors before installing
modules.
b.
Make sure cables are clear of insertion slot.
c.
Slide module into slot until it contacts backplane.
d.
Carefully push on ejector handles at top and bottom of module until module fully
seats.
4-14
to start reboot.