6. Software Control – Lightware Device Controller Software
6.7.2. Device Information
Basic information about the matrix frame and about the installed
boards are listed on this tab:
CPU board with controllers
Motherboard type and version
Input boards with Slot number
Output boards with Slot number
6.7.3. Status
The Health status of the matrix frame is displayed on this tab by showing
internal measurement values:
CPU Voltage levels
Battery cell Voltage level
Further internally applied Voltage levels
Internal temperature
The RPM values of the fans
Press the Refresh button to show/update values.
Battery Low Alert
The warning shows that the battery on the CPU board is exhausted
or not inserted. The function of the battery is powering the real time
clock when the frame is powered down. The low battery does not
affect normal operation of the matrix. However the error log will not
have correct time stamps.
Replacement Steps
Step 1. Switch off the matrix and
take
out
the
MX-CPU2
board. Locate the battery
holder. Check if the battery is
contacting well in the holder.
Step 2. Take the battery out firmly
taking care not to bend the
spring contact upwards. Bend
the spring contact a little bit
downwards to ensure good
contact.
Step 3. If the battery is exhausted,
replace with lithium button
battery type CR2032.