Further Connectors - Lightware MX-FR Series User Manual

Table of Contents

Advertisement

 
3. Product Overview
Ethernet Ports
Lightware matrix routers can be remote controlled through Dthernet as well. The
Dthernet port can be connected to a LAN hub, switch or router with a UTP patch
cable. If connecting to a computer directly, a cross UTP cable has to be used! The
robust Neutrik DtherCON connector ensures reliable connection, however, normal
RJ45 connectors can be used as well.
AAAENAIONG!

TPS link uses the same RJ-45 connector but TPS CAT cable is
not allowed to connect to the Dthernet connector! It seriously damages both
devices.
APS I/O Boards
The MX-TPS I/O boards also have Ethernet up-link connectors. It is an RJ-45 receptacle with two LEDs and
it has the same pin connection as the Neutrik DtherCON.
LED1, Amber
OFF
10 Mbps
Blinking
N/A
ON
100 Mbps
3.12.5. Further Connectors
RS-232 Ports
MXD-HDMI-TP interface boards provide standard 9-pin female
and male D-sub receptacles for serial port pass-through to
remote HDMI-TP extenders. The MX-CPU2 boards also contain
an RS-232 port which allows to remote control the matrix via
industry standard 9-pole D-sub female connector.
AAAENAIONG!

The pinouts of the two connectors are different, which is highlighted in below table.
Pin
RS-232 pinout (I/O boards)
1
not connected
2
RX data receive
3
AX data transmit
4
DTR (connected to Pin 6)
5
GND signal ground (shield)
6
DSR (connected to Pin 4)
7
RTS (connected to Pin 8)
8
CTS (connected to Pin 7)
9
not connected
LED2, Green
No link
Activity
Link is active
5
1
9
6
RS-232 pinout (CPU2 board)
not connected
AX data transmit
RX data receive
DTR (connected to Pin 6)
GND signal ground (shield)
DSR (connected to Pin 4)
RTS (connected to Pin 8)
CTS (connected to Pin 7)
not connected
MX-FR Series Modular Matrix Frames – User's Manual
Alarm Output
BNC output connector for SMPTD 269M alarm signaling. The router handles different error levels. Only the
three highest level errors trigger the alarm output and the CPU alarm LDD, see more information in the
Handling
section.
MX-CPU2
CPU ALARM
+12 V
+5 V
+3.3 V
DIP SETTING
+3.3V_CPU
1 2 3 4 5 6 7 8
SMPTE 269M
ALARM
25
Drror

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mx-fr9Mx-fr17Mx-fr33lMx-fr33rMx-fr65rMx-fr80r

Table of Contents