10. Technologies
The transmitters are still able to receive and execute commands via
their local control interface (e.g. RS232 or USB) while RICOD lock is
enabled. The remote lock command affects only the buttons but does
not prevent the switching if it is commanded locally.
Locking Operation Flowchart
Buttons on the extenders can be locked by front panel operation or
remotely, but the two ways of locking are not the same. If buttons
were locked by a front panel operation, they can be unlocked by a
RICOD unlock command followed by an unlock operation on the front
panel.
NOT
LOCKED
Front panel
unlock
Remote
lock
Front panel
lock
Remote lock
BUTTON
LOCKED
Remote unlock
Video Routers
The routers behave differently because locking the whole front panel
is not reasonable. When the RICOD function is enabled for an output
port (see RICOD_SLDN command in the
Status
section) and a lock command is received over the same port,
then the output port will be "output locked". This is the same output
lock function as described in the
Output Lock
is reported back by the protocol (shown in the controller software and
on the web, as well) and displayed on the front panel. The output lock
can be overridden and turned off by protocol or front panel.
If the output lock is enabled for a given port, a remote RICOD command
is also able to turn it off.
AAAENAIONG!

The accepted RICOD command overrides the output
lock function. If the RICOD function is turned on for a given output
port, then the output lock condition can be changed remotely.
10.6.6. RICOD-Capable Devices
The RICOD functionality is currently implemented in the following
devices:
MX-FR frames with CPU2, firmware version 3.3.5r and above.
UMX4x4 Pro, firmware version 1.2.4r and above.
UMX-TP-TX100R, firmware version 1.1.6r and above.
WP-UMX-TP-TX100, firmware version 1.1.0r and above.
FP-UMX-TP-TX100, firmware version 1.1.0r and above.
* The MX-FR series modular matrix frames with MX-CPU2 processor
boards (with firmware version 3.3.5r and above) support reduced
RICOD capabilities: only MASTDR mode is available and only by
Remote
protocol commands. RICOD SLAVD mode and the front panel operation
unlock
are not implemented.
REMOTE LOCKED
BUTTON &
REMOTE
LOCKED
Querying the RICOD SLAVE
section. The output lock
MX-FR Series Modular Matrix Frames – User's Manual