7.6

Fault/Status messages

Status
00h
FFh
Error messages triggered by the identification system
Status
02h
03h
04h
05h
06h
07h
08h
09h
0Ah
0Bh
0Ch
66
: 2 bytes ASCII, hexadecimal encoding, 01 ... 0C (01=January,
0C=December)
: 1 bit, password mode, 0 (0b): Mode off, 1 (1b): Mode on
: 4 bytes HEX, password
: 1 byte, increases by 1 after each response and confirmation. The
reply counter starts from 0 after the system is switched on. When the
maximum value is reached, the counter skips the value 0 (from 255 to
1).
: 3 (011b) or 4 (100b)
: 1 byte ()
: 1 bit, toggle bit
: 2 ASCII characters, for example: '02' for IPC02
: 8 bits
0 (00000000b): Trigger mode off
1 (00000001b): Trigger mode on
2 (00000010b): Trigger mode inverted
: 2 bytes, word start address in the data carrier, range from 0000h to
FFFFh, depending on tag type.
: 4 bits, number of words to be read or written, range from 0h to Fh,
depending on tag type. The following applies for IPC03: The word
count 0h is used with the word address 0000h to read the preset data
range on the data carrier ("Default Read").
: 2 bytes ASCII, hexadecimal encoding, 00h ... 63h
Meaning
The command has been executed without error.
The command is processing.
Meaning
Reserved
Reserved
Incorrect or incomplete command or parameter not in the valid range.
No data carrier in the detection range.
Hardware error, e.g. error during self-test or R/W head defect.
Internal device error.
Reserved
The parameterized tag type is not compatible with the connected reading head.
Reserved
Reserved
Reserved