Data 00; Data; Byte; Command Code (Bfh) - Pepperl+Fuchs IC-KP-B7-V95 Manual

Identcontrol interface with devicenet interface
Table of Contents

Advertisement

IC-KP-B7-V95
Appendix A
Ele-
Implicit
ment
telegram
2

Byte 8

Byte 9
Byte 10
Byte 11
byte 12
Byte 13
Byte 14
Byte 15
3
Byte 16
Byte 23
4
Byte 24
Byte 31
Note!
The input and output instances can be configured via the display. However,
setting should be performed via the program while the plant is operating to permit
easier replacement or extension to the plant.
Sending a write command as an implicit command
Ele-
Implicit
ment
telegram
1
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Use
Command code
Number of double words/
Channel/Toggle bit
Status
Reply counter
...
...
Use
Command code
Number of double words/
Channel/Toggle bit
Address of double word
(high byte)
Address of double word
(low byte)

Data

Data
Data
Data
Con-
Description
tents
04h
Command CT (Change tag)
04h
Channel = element = 2
Toggle bit = 0
00h
Processing command.
02h
For every IDENT telegram,
the value on the reply counter
increases by 1.
00h
Not used
00h
Not used
00h
Not used
00h
Not used
00h
No commands are
transmitted to channel 3.
00h
No commands are
transmitted to channel 4.
Con-
Description
tents
40h
Command SW
(Single write double words)
10h
1 double word = 4 bytes
Element defines the channel.
Toggle bit = 0
00h
Start address = 0
00h
Start address = 0
00h
1. Byte data
01h
2. Byte data
02h
3. Byte data
03h
4. Byte data
81

Advertisement

Table of Contents