7.2.9

Fault/Status messages

Status
Error messages which triggered the identification system
Status
: = "U0" (high byte = 0x55, low byte = 0x30)
: 1 bit, toggle bit
: 2 ASCII characters, example: "02" for IPC02
: 8 bits
0 (00000000
b
1 (00000001
b
2 (00000010
b
: 2 bytes, word start address in the read/write tag, range from 0000h to
FFFF
, depending on read/write tag type.
h
: 4 bits, number of words to be read or written, range from 0
depending on read/write tag type.
The following applies to IPC03: The word count 0h is used with the
word address 0000
("Default Read").
The following applies to IQC33: The word count parameter must be
even-numbered because of the block size of 8 bytes. The word address
then indicates the offset in 8-byte increments.
: 2 bytes ASCII, hexadecimal coding, 00
Meaning
00h
The command has been executed without error.
FFh
The command is processing.
Meaning
01h
The battery of the read/write tag is weak.
02h
Reserved
03h
Reserved
04h
Incorrect or incomplete command or parameter not in the valid
range.
05h
No data carrier in the detection range.
06h
Hardware error, e.g. error during self-test or R/W head defect.
07h
Internal device error.
08h
Reserved
09h
The parameterized tag type is not compatible with the connected
reading head.
0Ah
Several tags in the detection range (UHF).
0Bh
Reserved
0Ch
Reserved
0Dh
Reserved
0Eh
Internal buffer overflow.
0Fh
Reserved
): trigger mode off
): trigger mode on
): trigger mode inverted
to read the preset data range on the read/write tag
h
h
to F
,
h
h
... 63
h
77