Assembly Attributes - Pepperl+Fuchs IC-KP-B7-V95 Manual

Identcontrol interface with devicenet interface
Table of Contents

Advertisement

IC-KP-B7-V95
Commands
attribute 4
attribute 3
attribute 2
attribute 1
7.1.8

Assembly attributes

The attributes of the output object (class 64h) and the input objects (class 65h)
appear in different combinations in the assembly object. 26 assembly instances
can be used in pairs for implicit communication and so there are 13 possible
combinations. These combinations can be selected either via the device display,
the attribute 100 from instance 0 of the assembly object or by specifying the
combination on the PLC (Forward Open).
Mixed
mode
Sepa-
rated
mode
* access to mixed mode instance for input/output command object
The following comparison shows the relationship between input and output
instances: Input instance = output instance + 50d.
A combination of the "heartbeat" and the ident status forms the output instance
112 and input instance 162. Refer to appendix B for a more detailed view of the
object model.
Output
Input
Channel size
instance
instance
1
100d
150d
8*
101d
151d
12*
102d
152d
32*
103d
153d
60*
104d
154d
8
105d
155d
12
106d
156d
32
107d
157d
60
108d
158d
8
109d
159d
12
110d
160d
32
111d
161d
60
112d
162d
0 / 10
2
3
4
5
(conf.)
8
8
8
12
12
12
32
32
32
60
60
60
8
8
8
8
12
12
12
8
32
32
32
8
60
60
60
8
Required/Generated
size
Output/Input byte
8 / 8
12 / 12
32 / 32
60 / 60
32 / 32
48 / 48
128 / 128
240 / 240
40 / 40
56 / 56
136 / 136
248 / 248