Identification of a drive enclosure in the rack:
1. Connect and log in to the HPE 3PAR Service Processor (SP).
a. Browse to the IP address https://<sp_ip_address>:8443/.
b. Enter the account credentials, and then click Login.
2. Open the Service Console main menu by clicking 3PAR StoreServ Service Console in the upper-left
corner.
3. On the main menu, select drive enclosures, select one of the drive enclosures from the list, and then
select Actions > Locate.
4. With locate active, check the front of the storage system and locate the drive enclosure that has the
Module Fault LED lit solid amber on the left bezel ear cap and also has all of the drives in the
enclosure with their Fault LEDs flashing amber. At the rear of the storage system on the identified
drive enclosure, the UID led will be flashing blue.
5. Make a note of the physical location of this drive enclosure in the rack.
Add a description in the software to describe the physical location of the drive enclosures in the
rack:
6. On the Service Console main menu, select drive enclosures, select the drive enclosures from the list,
and then select Actions > Edit.
7. Follow the instructions on the dialog that opens. For example, you can enter the description of the
physical location of the expansion drive enclosure as Rack <xx> Rack-Unit <yy>.