System Commands; Querying The Product Name; Setting The Device Label; Querying The Serial Number - Lightware MX2-8x8-HDMI20-L User Manual

Multimedia matrix switcher
Hide thumbs Also See for MX2-8x8-HDMI20-L:
Table of Contents

Advertisement

 
7. LW3 Programmers' Reference
8.3. System Commands
8.3.1. Querying the Product Name
The name of the product is a read-only parameter and cannot be modified.
Command and Response
Ý GET·/.ProductName
pr·/.ProductName=<Product_name>
Ü
Parameters
The
<Product_name>
is the type of the device: read-only parameter and cannot be modified.
Example
Ý GET /.ProductName
Ü pr /.ProductName=MX2-24x24-DH-12DPi-R
8.3.2. Setting the Device Label
The device label can be changed to a custom text which is displayed in many windows of the LDC.
ATTENTION! This writable parameter is not the same as the ProductName parameter.
Command and Response
SET·/MANAGEMENT/UID/DeviceLabel=<Custom_name>
Ý
pw·/MANAGEMENT/UID/DeviceLabel=<Custom_name>
Ü
Parameters
The
<Custom_name>
may consist of ASCII characters and can be 32 characters length. Longer names are
truncated.
Example
Ý SET /MANAGEMENT/UID.DeviceLabel=MX2_Control_room
Ü pw /MANAGEMENT/UID.DeviceLabel=MX2_Control_room
8.3.3. Querying the Serial Number
Command and Response
Ý GET·/.SerialNumber
pr·/.SerialNumber=<serial_nr>
Ü
Example
Ý GET /.SerialNumber
Ü pr /.SerialNumber=87654321
MX2-HDMI20 series – User's Manual
8.3.4. Resetting the Matrix
The matrix can be restarted – the current connections (LAN, RS-232) will be terminated.
Command and Response
Ý CALL·/SYS:softReset()
Ü mO·/SYS:softReset=
Example
Ý CALL /SYS:softReset()
Ü mO /SYS:softReset=
8.3.5. Restoring the Factory Default Settings
The device is restarted, current connections are terminated, and the default settings are restored. See the
complete list in
Factory Default Settings
Command and Response
Ý CALL·/SYS:factoryDefaults()
Ü mO·/SYS:factoryDefaults=
Example
Ý CALL /SYS:factoryDefaults()
Ü mO /SYS:factoryDefaults=
8.3.6. Switching to Standby Mode
The video transmission is disabled, the LCD is switched off, but remote connections (LAN, RS-232) remain
enabled in standby mode. See the
Command and Response
Ý CALL·/MANAGEMENT/POWER:standby()
Ü mO·/MANAGEMENT/POWER:standby=
Example
Ý CALL /MANAGEMENT/POWER:standby()
Ü mO /MANAGEMENT/POWER:standby=
8.3.7. Switching to Normal Mode
If the matrix is in Standby mode, it can be switched back to Normal mode as follows:
Command and Response
Ý CALL·/MANAGEMENT/POWER:wakeUp()
Ü mO·/MANAGEMENT/POWER:wakeUp=
Example
Ý CALL /MANAGEMENT/POWER:wakeUp()
Ü mO /MANAGEMENT/POWER:wakeUp=