7. LW3 Programmers' Reference
8.10.3. Loading a Preset
Command and Response
Ý CALL·/MEDIA/PRESET/<preset_name>:load()
Ü mO·/MEDIA/PRESET/<preset_name>:load=Ok
Example
Ý CALL /MEDIA/PRESET/My_pres:load()
Ü mO /MEDIA/PRESET/My_pres:load=Ok
Explanation
'My_pres' preset has been loaded and applied.
8.10.4. Renaming a Preset
Command and Response
Ý CALL·/MEDIA/PRESET:rename(<Old_name>,<New_name>)
Ü mO·/MEDIA/PRESET:rename=
Example
Ý CALL /MEDIA/PRESET:rename(My_Pres,Your_Pres)
Ü mO /MEDIA/PRESET:rename=
Explanation
The preset has been renamed to 'Your_Pres'.
MX2-HDMI20 series – User's Manual
8.11. RS-232 Port Settings
INFO: The current setting can be queried by using the
8.11.1. Setting the Current Command Protocol
Command and Response
SET·/MANAGEMENT/SERIAL.Protocol=<prot_mode>
Ý
pw·/MANAGEMENT/SERIAL.Protocol=<prot_mode>
Ü
Parameters
Identifier
Parameter description
<prot_mode>
The applied protocol of
the RS-232 port
Example
Ý SET /MANAGEMENT/SERIAL.Protocol=LW3
Ü pw /MANAGEMENT/SERIAL.Protocol=LW3
8.11.2. Setting the Baud Rate
Command and Response
SET·/MANAGEMENT/SERIAL.Baudrate=<BAUD_value>
Ý
pw·/MANAGEMENT/SERIAL.Baudrate=<BAUD_value>
Ü
Parameters
The following values are accepted: 200, 300, 600, 1200, 1800, 2400, 4800, 9600, 19200, 38400, 57600,
115200.
Example
Ý SET /MANAGEMENT/SERIAL.Baudrate=57600
Ü pw /MANAGEMENT/SERIAL.Baudrate=57600
GET
command.
Parameter values
LW2: Lightware Protocol #2 is applied.
LW3: Lightware Protocol #3 is applied.
P#2: The additional P#2 protocol is applied.