2 CALCULATION OF SETTINGS
Table 2–14: GENERAL SETTINGS DATA SHEET (Sheet 1 of 2)
NO.
MNEMONIC
DESCRIPTION
CONFIGURE
101
UNITID
Unit ID
102
SYSFREQ
System Frequency
103
PHASROTATE
Phase Rotation
104
TIMESYNCH
Time Synch Source
105
NUM_BKR
Number of Breakers
106
NUM_TC
Number of Trip Circuits
107
NUM_MON
Number of Trip Circuit Monitors
108
DISPLAYVAL
Value Display Mode
109
LANGUAGE
Language Option
110
SYSIN1-4
System Inputs 1 to 4
COMMPORTS
201
COMPORT1
Communications Port #1
Settings
202
COMPORT2
Communications Port #2
Settings
203
COMPORT3
Communications Port #3
Settings
204
PROTOCOL1
Communications Port #1
Protocol
205
PROTOCOL2
Communications Port #2
Protocol
206
PROTOCOL3
Communications Port #3
Protocol
OSC_GRAPHY
301
NUMFAULTS
Number of Fault Records
302
PREFAULT
Number of Pre-fault Cycles
303
SPLITREC
Splits Fault Record and
captures this percentage at end,
with 1-SPLITREC captured at
beginning
BRKR DUTY
401
EXPONENT
Exponent in I
402
MAX_OP
Maximum Number of Breaker
Operations for a Breaker
403
MAX_IXT
Maximum Breaker Duty for a
Breaker
† Applicable to the Single Phase Tripping model only.
‡ Applicable to the Three Phase Tripping model only.
* Contact converter output normally appears as a Logic 1 with normally open contact connected; to invert output to Logic 0, add 1000 to
the number
GE Power Management
RANGE (5A & 1A)
0000 to 9999
50 Hz, 60 Hz
ABC, ACB
INTERNAL, IRIG-B
1, 2
1, 2
for 1P tripping:
format = abcdef;
for 3P tripping:
format = abcd
PRI, SEC
ENGLISH, SPANISH
0000 to 1111 (binary)
0 to 15 (decimal)
Baud Rate (xx), Parity
(y), Stop Bits (z)
format = xxyz
Interface (i), Baud Rate
(xx), Parity (y), Stop Bits
(z)
format = ixxyz
Interface (i), Baud Rate
(xx), Parity (y), Stop bits
(z)
format = ixxyz
GE-MODEM, ASCII
GE-MODEM, ASCII
GE-MODEM, ASCII
2,4,8,12
(std. mem.)
6,12,24,36
1 to 8
0 to 100%
x
1.0 to 2.0
t calculation
0 to 9999
0 to 9999999 A
ALPS Advanced Line Protection System
2.5 REFERENCE TABLES

2.5.5 GENERAL SETTINGS DATA SHEETS

STEP
1
N/A
N/A
N/A
N/A
N/A
a-f = 0 (on) or 1(off)
N/A
N/A
1
xx = 03, 12, 24, 48, 96,
19;
y = 0 (none), 1 (odd), 2
(even);
z = 1, 2
i = 0 (RS232), 1
(RS485); xx = 03, 12,
24, 48, 96, 19; y = 0
(none), 1 (odd), 2
(even);
z = 1, 2
i = 0 (RS232), 1
(RS485); xx = 03, 12,
24, 48, 96, 19; y = 0
(none), 1 (odd), 2
(even);
z = 1, 2
N/A
N/A
N/A
N/A
(exp mem)
1
1
0.1
1
x
100
sec.