2.5 REFERENCE TABLES
Table 2–13: PROTECTION SETTINGS DATA SHEET (Sheet 5 of 7)
NO.
MNEMONIC
1408
PTRATIO
SCADA_DTA
1501
FLTLOCK
1502
FLTRESET
2
1601
MOBZONE
OS BLOCKING
1602
MOBCHARANG
1603
BLOCKWHAT
1604
BLOCKZ1
1605
BLOCKZ2
1606
BLOCKZ3
1607
BLOCKZ4
OS TRIPPING (OUT-OF-STEP TRIPPING MODELS ONLY)
1701
USE_OST
1702
NUMBRCHAR
1703
TRIPIN_OUT
1704
FWDREACH
1705
REVREACH
1706
OUTER
1707
MIDDLE
1708
INNER
1709
TLOS1PU
1710
TLOS1DO
1711
TLOS2PU
1712
TLOS3PU
1713
TLOS4PU
RECLOSER
1801
RECLMODE
^
RECTYPE
1802
^
NUM1P
1803
^
1PDELAY1
1804
^
1PDELAY2
1805
^
1PDELAY3
1806
^
1PDELAY4
1807
1808
NUM3P
1809
3PDELAY1
1810
3PDELAY2
1811
3PDELAY3
1812
3PDELAY4
1813
RESETTIME
1814
DWELLTIME
† Setting value QUAD applies to Revision B models only.
‡ Setting applicable to Revision B models only.
^ Setting applicable to Single Phase Tripping models only.
2-70
DESCRIPTION
PT Ratio
Hold Time
Fault Location Reset Time
Coordinating Zone
MOB Characteristic Angle
Block during OS
Block all Zone 1 Functions
Block all Zone 2 Functions
Block all Zone 3 Functions
Block all Zone 4 Functions
Select OST
Select Number of Characteristics
Trip Entering or Leaving Inner
OST Forward Reach
OST Reverse Reach
Outer Characteristic Angle
Middle Characteristic Angle
Inner Characteristic Angle
Coordinating Timer 1 Pickup
Coordinating Timer 1 Dropout
Coordinating Timer 2 Pickup
Coordinating Timer 3 Pickup
Coordinating Timer 4 Pickup
Select Reclosing Option
Set Reclosing Type
Number of Attempts Following 1P
Trip
1 Pole First Delay
1 Pole Second Delay
1 Pole Third Delay
1 Pole Fourth Delay
Number of Attempts Following 3P
Trip
3 Pole First Delay
3 Pole Second Delay
3 Pole Third Delay
3 Pole Fourth Delay
Reset Time
Contact Dwell Time
ALPS Advanced Line Protection System
2 CALCULATION OF SETTINGS
RANGE (5A)
RANGE (1A)
1 to 7000 step 1
0 to 99.9 sec. step 0.1
0 to 999 minutes step 1
ZONE2, ZONE3, ZONE4
30 to 130 deg. step 1
BLKALL, BLKDIST, BLKPHAS, BLKNONE
NO, YES
NO, YES
NO, YES
NO, YES
NO, YES
2, 3
IN, OUT
0.1 to 75.0 ohms
0.5 to 375.0 ohms
step 0.1
step 0.5
0.1 to 75.0 ohms
0.1 to 375.0 ohms
step 0.1
step 0.5
40 to 165 deg. step 1
40 to 165 deg. step 1
40 to 165 deg. step 1
1 to 100 msec. step 1
1 to 100 msec. step 1
1 to 100 msec. step 1
1 to 100 msec. step 1
1 to 100 msec. step 1
OFF, NONE, INTERNAL, EXTERNAL, BOTH
1POLE, 3POLE, 1POLE/3POLE
1 to 4 step 1
0.1 to 300 sec. step 0.1
0.1 to 300 sec. step 0.1
0.1 to 300 sec. step 0.1
0.1 to 300 sec. step 0.1
1 to 4 step 1
0.1 to 300 sec. step 0.1
0.1 to 300 sec. step 0.1
0.1 to 300 sec. step 0.1
0.1 to 300 sec. step 0.1
0.1 to 300 sec. step 0.1
0.1 to 2 sec. step 0.1
USER
SETTING
GE Power Management

Advertisement