B.2 REGISTER MAPS
Table B–4: MODBUS MEMORY MAP (Sheet 6 of 10)
ALPS
CONTENTS
REGISTER
3248
IPT_PICKUP
3249
IPB_PICKUP
3250
IPBKFACTOR
B
3251
NT_OFFSET
3252
UNBALALARM
PROTECTION SETTINGS: OVERCURRENT
3253
50
3254
50_DIRCNL
3255
50PICKUP
3256
50PICKUPFF
3257
50G
3258
50G_DIRCNL
3259
50GPICKUP
3260
50GPICKUPFF
3261
50GRESTNT
3262
51G
3263
51G_DIRCNL
3264
51GPICKUP
3265
51GPICKUPFF
3266
51GCURVE
3267
51GTIMDIAL
3268
DEFTIMDELY
3269
51G_RESET
PROTECTION SETTINGS: VOLTAGE
3270
RATEDVOLTS
3271
PHASEOVER
3272
PHOVPICKUP
3273
PHOVTMDLY
3274
V1OVER
3275
V1OVINSTPU
3276
V1OVTIMPU
3277
V1OVTIMDLY
3278
V1COMP
3279
V1COMPRCH
3280
V1COMPINPU
3281
V1COMPTDPU
3282
V1COMPTDLY
3283
FUSEFAIL
PROTECTION SETTINGS: BLOCK RECLOSING
3284
ALL_BELOW
3285
OUTOFSTEP
3286
ALL_3_Z2PH
3287
50G_BLOCK
3288
Z2TIMETRIP
3289
Z3TIMETRIP
1, 2, 3, 4, 5, 6, 7, 8
See page B–14 for footnote explanations.
B-10
TYPE
FORMAT
NO. OF
REGS.
R/W
P100
1
R/W
P100
1
R/W
Unsigned Int
1
R/W
P100
1
R/W
Unsigned Int
1
R/W
Unsigned Int
1
R/W
Unsigned Int
1
R/W
P10
1
R/W
Float
1
R/W
Unsigned Int
1
R/W
Unsigned Int
1
R/W
P10
1
R/W
P10
1
R/W
Unsigned Int
1
R/W
Unsigned Int
1
R/W
Unsigned Int
1
R/W
P100
1
R/W
P100
1
R/W
Unsigned Int
1
R/W
P10
1
R/W
P10
1
R/W
Unsigned Int
1
R/W
Unsigned Int
1
R/W
Unsigned Int
1
R/W
P100
1
R/W
P100
1
R/W
Unsigned Int
1
R/W
P100
1
R/W
P100
1
R/W
P100
1
R/W
Unsigned Int
1
R/W
P100
1
R/W
P100
1
R/W
P100
1
R/W
P100
1
R/W
Unsigned Int
1
R/W
Unsigned Int
1
R/W
Unsigned Int
1
R/W
Unsigned Int
1
R/W
Unsigned Int
1
R/W
Unsigned Int
1
R/W
Unsigned Int
1
ALPS Advanced Line Protection System
RANGE
UNITS
1 A
5 A
10 to 500
50 to 2500
A
5 to 75
25 to 375
A
0 = 0.0; 1 = 0.066
0 to 100
0=No, 1=Yes
0=No, 1=Yes
0=No, 1=Yes
4 to 320
20 to 1600
A
4 to 320
20 to 1600
A
0=No, 1=Yes
0=No, 1=Yes
1 to 160
5 to 800
A
1 to 160
5 to 800
A
0 = 0.0; 1 = 0.3
0=No, 1=Yes
0=No, 1=Yes
4 to 300
20 to 1500
A
4 to 300
20 to 1500
A
0=Inv, 1=V-Inv, 2=E-Inv,
3=Custom, 4=DefT
5 to 100
5 to 300
sec.
0 = Fast, 1 = EM
100, 105, 110, 115, 120
V
0=No, 1=Yes
0 to 140
pu V
0 to 1000
sec.
0=No, 1=Yes
100 to 140
pu V
100 to 140
pu V
0 to 1000
sec.
0=No, 1=Yes
5 to 25000
1 to 5000
100 to 140
pu V
100 to 140
pu V
0 to 1000
sec.
0=No, 1=Yes
0=No, 1=Yes
0=No, 1=Yes
0=No, 1=Yes
0=No, 1=Yes
0=No, 1=Yes
0=No, 1=Yes
GE Power Management
APPENDIX B
DEFAULT
1 A
5 A
15
75
5
25
-
1
0.25
0.05
-
1
-
0
-
1
40
200
60
300
-
1
-
1
20
100
60
300
-
1
-
1
-
1
20
100
40
200
-
1
-
50
10
-
0
115
-
0
1
50
-
0
125
125
25
-
0
3000
600
140
140
150
30
-
1
-
0
-
0
-
0
-
0
-
0
-
0