GE ALPS Instruction Manual page 116

Advanced line protection system
Table of Contents

Advertisement

2.5 REFERENCE TABLES
Table 2–10: INDEX NUMBERS –
ALPS with Single Phase Tripping
Index
Description
33
Trip Bus Phase A
34
Trip Bus Phase B
35
Trip Bus Phase C
2
36
1P Reclose Initiate
37
3P Reclose Initiate
38
Reclose Cancel Output from Scheme
Logic
39
KEY XMTR1/CARR START Output from
Scheme Logic
40
KEY XMTR2/CARR STOP Output from
Scheme Logic
41
3 Phase Trip Enable
42
Spare
43
Spare
44
Reclose in Progress
45
Line Over Load Alarm Output
46
Critical Alarm Output
47
Recloser Lockout Alarm
48
Trip Circuit Alarm
49
Zone Flags On Alarm
50
Overcurrent Alarm
51
Unbalanced Current Detector Alarm
Output
52
Non-Critical Alarm Output
53
Spare
54
Spare
55
Spare
56
MANUAL OPEN BRK1
57
MANUAL OPEN BRK2
58
MANUAL CLOSE BRK1
59
MANUAL CLOSE BRK2
60
Fault ID: Phase A Involved
61
Fault ID: Phase B Involved
62
Fault ID: Phase C Involved
63
Fault ID: Neutral Involved
64
DMA Overrun
65
Zone 1 AB Distance Function
66
Zone 1 BC Distance Function
67
Zone 1 CA Distance Function
68
Zone 2 AB Distance Function
69
Zone 2 BC Distance Function
70
Zone 2 CA Distance Function
71
Zone 3 AB Distance Function
72
Zone 3 BC Distance Function
73
Zone 3 CA Distance Function
74
Zone 4 AB Distance Function
75
Zone 4 BC Distance Function
2-52
SCHEME, RECLOSER, & PROGRAMMABLE LOGIC
ALPS with Three Phase Tripping
Mnemonic
Index
TRIPA
33
TRIPB
34
TRIPC
35
RI-1P
36
RI-3P
37
CANCL
38
KEY1
39
KEY2
40
TRIP3P
41
42
43
RIP
44
LNOVLD
45
CRTALM
46
LORCL
47
TCMALM
48
ZNALM
49
OVRALM
50
UNBAL
51
NCALM
52
53
54
55
MNOPN1
56
MNOPN2
57
MNCLS1
58
MNCLS2
59
DAFLTA
60
DAFLTB
61
DAFLTC
62
DAFLTN
63
DMAOVR
64
Z1AB
65
Z1BC
66
Z1CA
67
Z2AB
68
Z2BC
69
Z2CA
70
Z3AB
71
Z3BC
72
Z3CA
73
Z4AB
74
Z4BC
75
ALPS Advanced Line Protection System
2 CALCULATION OF SETTINGS
(Sheet 1 of 5)
Description
Trip Bus
Spare
Spare
Spare
3P Reclose Initiate
Reclose Cancel Output from Scheme
Logic
KEY XMTR1/CARR START Output from
Scheme Logic
KEY XMTR2/CARR STOP Output from
Scheme Logic
Spare
Spare
Warm Restart
Reclose in Progress
Line Over Load Alarm Output
Critical Alarm Output
Recloser Lockout Alarm
Trip Circuit Alarm
Zone Flags On Alarm
Overcurrent Alarm
Unbalanced Current Detector Alarm
Output
Non-Critical Alarm Output
Key 3
Key 4
Spare
MANUAL OPEN BRK1
MANUAL OPEN BRK2
MANUAL CLOSE BRK1
MANUAL CLOSE BRK2
Fault ID: Phase A Involved
Fault ID: Phase B Involved
Fault ID: Phase C Involved
Fault ID: Neutral Involved
DMA Overrun
Zone 1 AB Distance Function
Zone 1 BC Distance Function
Zone 1 CA Distance Function
Zone 2 AB Distance Function
Zone 2 BC Distance Function
Zone 2 CA Distance Function
Zone 3 AB Distance Function
Zone 3 BC Distance Function
Zone 3 CA Distance Function
Zone 4 AB Distance Function
Zone 4 BC Distance Function
GE Power Management
Mnemonic
TRIP
RI
CANCL
KEY1
KEY2
WARMST
RIP
LNOVLD
CRTALM
LORCL
TCMALM
ZNALM
OVRALM
UNBAL
NCALM
MNOPN1
MNOPN2
MNCLS1
MNCLS2
DAFLTA
DAFLTB
DAFLTC
DAFLTN
DMAOVR
Z1AB
Z1BC
Z1CA
Z2AB
Z2BC
Z2CA
Z3AB
Z3BC
Z3CA
Z4AB
Z4BC

Advertisement

Table of Contents
loading

Table of Contents