Is A Message Displayed On The Screen; Are The Cables Connected; Is The Status Led For The Lan Cable Connector Lit In Green; Are The Lan Settings Correct - Roland VersaUV LEF2-200 User Manual

Hide thumbs Also See for VersaUV LEF2-200:
Table of Contents

Advertisement

Is a message displayed on the screen?

RELATED LINKS
・  P. 190 "Messages"
・  P. 193 "Error Messages"

Are the cables connected?

Connect the cable securely.

Is the status LED for the LAN cable connector lit in green?

If the status LED (
) for the LAN cable connector is not lit in green, the network connection has not been made
correctly. Check whether or not the network routing is appropriate. Try connecting the computer and the machine
to the same hub or connecting them directly using a crossover cable. If this makes it possible to perform output, it
means the problem is in the network itself.

Are the LAN settings correct?

If printing is not possible even though the link LED for the Ethernet connector is lit, make sure the IP address and
other settings are appropriate. The settings on both the machine and the computer must be appropriate. Redo the
settings, checking to ensure that the IP address does not conflict with the IP address for another device on the
network, that the port setting for the software RIP specifies the IP address set on the machine, that the settings
have no typing errors, and for other such problems.

Did the software RIP end abnormally?

Make sure the software RIP is running correctly, and then switch the sub power switch off and back on.

Is the temperature of the room too low?

Use the machine in an environment with an ambient temperature of 20 to 32°C (68 to 90°F).
The Printer Unit Does Not Run