Class 1 Laser Product Notice; Library Status Indicators; Library Status Indicators (Front Control Panel) - Oracle StorageTek SL150 Manual

Modular tape library
Hide thumbs Also See for StorageTek SL150:
Table of Contents

Advertisement

The front control panel touch screen is also used to perform basic initialization
setup with an initialization wizard.
Additional library management functions are performed by the administrator
using the remote management interface.
The SL150 Library supports partitions. Each partition has an assigned bridged tape
drive, and each partition behaves as an independent library. All partitions share the
use of the single robot, reserved slots, and mailslot.

Class 1 Laser Product Notice

The StorageTek SL150 Modular Tape Library contains a class-1 laser as defined by IEC
60825-1 Ed. 2 (2007).

Library Status Indicators

Library status indicators are located on the front control panel above the left cartridge
magazine (see
replaceable unit [CRU] in the dark rectangle to the left of the robot lock (see
Figure
Figure 1–3 Library Status Indicators (Front Control Panel)
Fault: a fault anywhere in the library triggers the fault indicator. Look for active
fault indicators on other CRUs.
OK: indicates an operational library.
When both the Fault and OK indicators are active at the same time, the library is in
a degraded state.
Code versions below 2.0 support two partitions, but code
Note:
versions 2.0 and above support up to eight partitions.
Use of controls or adjustments or performance of
Warning:
procedures other than those specified herein may result in
hazardous radiation exposure.
Figure
1–3) and at the rear of the library on the robot customer
3–1).
Library Status Indicators
Product Overview 1-3

Advertisement

Table of Contents
loading

Table of Contents