DAKOTA ULTRASONICS MiniMax v2.0 Operation Manual page 64

Ultrasonic bolt tension monitor
Table of Contents

Advertisement

Dakota Ultrasonics
21) Press the
items until ACCEPT CAL is highlighted.
22) Press the
to cancel the calibration.
23) Press the
AUTO list until CALC ZERO is highlighted.
24) Press the
zero values, or
Note: If
was pressed to calculate the new values, pressing the
once will display the CAL menu to review the new ZERO value calculated.
Note: In order for the MiniMax to display the correct measurement value for
documentation purposes in the CAL DATA group created in the previous
section, the material velocity calculated during the calibration process and
temperature coefficient must be set to the same values as in the calibration
section. Additionally, the Stress Factor must be set to 1.000.
and
arrow keys multiple times to scroll the hot menu
key to accept the calibration and return to the AUTO list, or
and
arrow keys multiple times to scroll through the
key to calculate, change, and display the new velocity and
to cancel the calibration.
58
key