If a successful parameter write request was performed (request ID = 0x02), bit M14 shall turn on.
In case of a failure (request ID = 0x82) bit M13 will be ON, and the error code will be stored in
D3504.
A8NDPV1 PROFIBUS Option Board
GX Works2 (Q-CPU) Simple Ladder Acyclic communication example