1.5

Environmental Specifications

Item
Operating Temperature
Storage Temperature
Relative Humidity
Vibration
Grounding
Power Supply
Cooling Method
Communication Speed
The A8NPDPV1 interface is lead-free / RoHS-compliant.
A8NDPV1 PROFIBUS Option Board
Specification
-10º to +50º Celsius (ambient of the drive, non-freezing)
-40º to +65º Celsius
93% non condensing
Max acceleration amplitude: 10 m/s
Max displacement amplitude: 3 mm at 2 - 9 Hz
Connected to inverter frame ground through the PE plate / isolated from
inverter control power common
Supplied from inverter
Self cooled
Up to 12 Mbit
Environmental Specifications
2
at 9 - 200 Hz
7