(2) Button feeder components

1) Removing the covers
5
2
3
2) Adjusting carrier pin
1. Adjusting the clearance between the carrier pin and the shutter plate
3
4
2
Button
carrier
6
2. Centering the carrier pin
8
3
4
1
6
5
1
R
Carrier pin
5
4
7
5
6
2
1
Before adjusting the button feeder components,remove
top cover 1, set plate 2 and front cover 3.
Remove screws 4, 5 and 6.
Loosen screws 2 and 3. Adjust clearance R provided
between the carrier pin and shutter plate 1, by turning
adjusting stopper 4, to 0.1 to 0.3 mm. At this time, fit
the button carrier against adjusting stopper 4 with no
clearance between them.
Then,tighten screw 3 to fix adjusting stopper 4 in
position.
Remove the work attachment from rotary rod 2.
Insert the carrier pin into centering ring 1. (At this
time,the shutter plate should be kept open.)
(Caution) Whenever the centering ring is used, set
it with its smaller diameter side up.
1) Adjusting the center of the carrier pin in the lateral
direction. Loosen screw 3 to allow the button
carrier to swing in the right or left as desired. Then
move the button carrier until the position where
rotary rod 2 smoothly enters centering ring 1 is
found.
Tighten screw 3 so that the button carrier is
secured at that position. Now,press eccentric cam
(1. -5) against the button carrier, and tighten screw
shown in (1.-6) while carefully preventing the
button carrier from moving from the secured
position.