2 Switches on CPU circuit board 4 (Refer to "(2) Inside the control box" on p.42.)
2
Switch
Switch
No.
name
SW1-1
This switch is used to switch over the characters indicated on the display screen from/to
Japanese/English.
Japanese (OFF) : The characters are indicated in Japanese.
English
(This switch is set to its ON position at the time of delivery.)
1
SW1-2
This switch is used to switch over the unit of length for the distance setting from/to mm/
inches.
mm
inch
(Caution) After switching over between mm and inches, all previously stored data will be
(This switch is set to its OFF position at the time of delivery.)
SW2-1
This switch is used to change over the automatic repeated operation of the sewing machine.
(This switch has been set to its OFF position at the time of ddelivery.)
2
SW2-2
This switch is used to change over the failure diagnostic feature.
(This switch has been set to its OFF position at the time of ddelivery.)
1
(Caution) Be sure to set SW2-3 and -4 to their
(ON) : The characters are indicated in English.
(OFF) : The length is set in mm.
(ON) : The length is set in inches.
cleared once the power switch is turned ON.
(OFF) : The sewing machine operates under the normal operation mode.
(ON) : The sewing machine operates under the automatic repeated operation
mode.
(OFF) : The sewing machine operates under the normal operation mode.
(ON) : The sewing machine operates under the failure dianostic mode. (Set
the DIP SW4-8, mounted on the I/O circuit board, also to its ON
position.)
OFF positions.