1 Switches on I/O circuit board 3 (Refer to "(2) Inside the control box" on p.42.)
(Caution) Set the SW1-1 and -8, SW4-5 through -8, and SW5-4 through -8 to their OFF positions, and set
the SW1-2 and -3, and SW4-1 and -2 to their ON positions.
Switch
Switch
No.
name
SW1-4
This switch is used to set the jump function.
(This switch has been set to its OFF position at the time of delivery.)
SW1-5
This switch is used to set the long-material mode.
1
(This switch has been set to its OFF position at the time of delivery.)
SW1-6
This switch is used to specify the frequency of power source (50 Hz or 60 Hz).
50 Hz
60 Hz
(This switch has been set to 50Hz/60Hz according to the destination of the machine.)
4
5
6
Description of function
(OFF) : The jump function cannot be specified.
(ON) : The jump function can be specified.
(OFF) : The long-material mode cannot be specified.
(ON) : The long-material; mode can be specified.
(OFF) : For the 50 Hz zone
(ON) : 60 Hz zone