JUKI ACF-164-1903 Engineer's Manual page 43

Button attaching indexer
Hide thumbs Also See for ACF-164-1903:
Table of Contents

Advertisement

!3
* * * * * * * * B U T T O N INDEX
5 4
P O W E R O F F → CHECK
Cause
: If the button index motor is
energized for a period of time
l o n g e r
predetermined time, the
above message will be
shown on the display screen.
How to reset : Turn OFF the power switch,
and check button index unit
2 for any clogged button.
Give two clockwise turns to
manual screw 4 using a
screwdriver after you have
confirmed that 2 would not
turn any further.
!4
* * * * * * * S E W I N G MACHINE
5 5
P O W E R O F F → CHECK
Cause
: If an error occurs in LK machine after sewing has started, the above message will be
shown on the display screen.
Also, if the sewing continues for 20 seconds or more, the message will be shown.
Consequently, this message may be shown after 20 seconds from the start of sewing.
How to reset : Turn OFF the power switch, and check the state of the LK machine.
!5
5 6
* * * * * * B U T T O N S E N S I N G O V E R E R R O R * * * * * *
C H E C K → R E S E T
Cause
: If a button is not detected
after the index unit has
continuously performed the
button sensing (indexing the
button and detecting the
existence of button) by ten
times or more, the above
message will be shown on the
display screen.
How to reset : Check parts feeder 3 for its
correct performance, and
adjust so that buttons are fed
to the index unit properly.
t h a n
t h e
→ S T A R T
39
ERROR * * * * * * * * *
2
4
ERROR * * * * * * *
3

Advertisement

Table of Contents
loading

Table of Contents