JUKI ACF-164-1903 Engineer's Manual page 48

Button attaching indexer
Hide thumbs Also See for ACF-164-1903:
Table of Contents

Advertisement

SW1-7
This switch is used for setting the pair-stacking function.
1
(This switch has been set to its OFF position at the time of delivery.)
SW2
This switch is used to set the length of time from the actuation of the button positioner
(triple pawl) to the detection of the button.
2
(The aforementioned length of time has been factory-set to "5" at the time of delivery.)
SW3
This switch is used to set the length of time from the completion of index of a button to the
time when the actuation of the button positioner (triple pawl) becomes possible.
3
(The aforementioned length of time has been factory-set to "1" at the time of delivery.)
SW4-3
This switch is used to set the function of detecting a button fed on the button clamp jaw
lever.
(This switch has been set to its OFF position at the time of delivery.)
4
SW4-4
This switch is used to set the function of detecting a button fed on the index unit.
(The switch has been factory-set to its OFF position at the time of delivery.)
SW4- □
5
6
7
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
(OFF) : The pair stacking mode cannot be selected.
(ON) : The pair stacking mode can be selected.
(ON) : The aforementioned button detecting function does not work.
(OFF) : The aforementioned button detecting function works.
(ON) : The aforementioned button detecting function does not work.
(OFF) : The aforementioned button detecting function works.
Waiting time of the spinner oscillating arm
Ditto
Ditto
Ditto
Ditto
Ditto
Fine positioning completion detection control
(Fine positioning completion switch is necessary.)
Both positioning and fine positioning detection control
290ms (Standard value)
190ms
390ms
490ms
590ms
690ms
44
Expected
control by
timer
Detection
control by
sensor

Advertisement

Table of Contents
loading

Table of Contents