a/b1
Relay
Actor2
Actor1
Door opener
Sensor
Connection of doorway equipment produced by Siedle
Note: The above diagram shows
the usage of the "PVG 402-0" module
(which merely serves as an example).
Other modules can also be operated,
such as its successor, "PVG 602-01".
36
Connectible Devices
PVG 402-0
Amplifier
To
Ts
-T
+T
To
Ts*
b
a
NG 402-02
Ac adapter
b
c
+
-
230 V ~
9
c1
7
LW
1
12
11
9
+
12 V ~
Siedle
11
12
9
+
Door bell