Cr Mode Setting Verification; Cp Mode Setting Verification - Chroma 63800 Series Operation & Programming Manual

Programmable ac/dc electronic load
Table of Contents

Advertisement

Source Setting
Voltage
Frequency
(V)
100
45/440

10.4.3 CR Mode Setting Verification

1. Press CR to enter CR mode.
2. AC Source settings are shown as Table 10-4. Please follow the model to set R, I
According to the model to confirm if the values of Meter & Load meet to that in Table 10-4.
Source Setting
Frequency
Voltage
(Hz)
45/440

10.4.4 CP Mode Setting Verification

Switch it to PF only mode, the procedures are as follows.
1. Press CONF./LOCAL.
2. Press 1 and ENTER to enter SETUP. (More information about the display, please
refer 3.6.1 BOTH mode).
3. Move the cursors of ▲ and ▼ to "1-5. CF/PF SETTING".
4. Press direction keys of ◄, ► or turn rotary knob to select "PF". (More information about
the display, please refer 3.6.1 BOTH mode).
5. Press CP to enter PF only mode.
Table 10-3
Load Setting
Current
I
p
(Hz)
(A)
5
18
5
36
5
45
Table 10-4
Load Setting
R (Ω)
I
rms
(V)
50
3
350
100
50
1.5
350
100
50
1.2
350
100
Meter & Load
Measurement
(max)
I Specification (A)
4.959~5.041
54
17.946~18.054
4.923~5.077
108
35.892~36.108
4.905~5.095
135
44.865~45.135
Meter & Load
Measurement
R Specification (Ω)
(max)
2.969~3.032
54
84.352~122.776
1.485~1.516
108
73.276~157.409
1.188~1.213
135
68.707~183.638
Verification
Model
63802
63803
63804
(max).
rms
Model
63802
63803
63804
10-5