Current Subsystem - Chroma 63800 Series Operation & Programming Manual

Programmable ac/dc electronic load
Table of Contents

Advertisement

Programmable AC/DC Electronic Load 63800 Series Operation & Programming Manual
Setting Parameter : none
Example
: PROT:CLE

8.6.3.1 Current Subsystem

[LOAD:]
CURRent
[:LEVel]
[:AMPLitude]
[:AC]
:DC
[:DC]
:HIGH
:MAX
[:LEVel]
[:AMPLitude]
:PEAK
:MAX
[:LEVel]
:LIMit
[LOAD:]CURRent [:LEV][:AMPL][:AC]
Description: This command sets the RMS current of the electronic load. The electronic load
insures that the load current stays constant at the set value.
Setting Syntax
: [LOAD:]CURRent [:LEV][:AMPL][:AC]
Setting Parameter : <NR2>, 63804 Range: 0 ~ 45, 63803 Range: 0 ~ 36, 63802 Range:
Query Syntax
: [LOAD:]CURRent [:LEV][:AMPL][:AC]?
Response Parameter: <NR2>
Example
: CURR 45
[LOAD:]CURR[:LEV][:AMPL]:DC
Description: This command sets the DC current of the electronic load. The electronic load
insures that the load current stays constant at the set value.
Setting Syntax
: [LOAD:]CURRent [:LEV][:AMPL]:DC
Setting Parameter : <NR2>, 63804 Range: 0 ~ 45, 63803 Range: 0 ~ 36, 63802 Range:
Query Syntax
: [LOAD:]CURRent [:LEV][:AMPL]:DC?
Response Parameter: <NR2>
Example
: CURR:DC 45
[LOAD:]CURR[:LEV][:AMPL][:DC]:FALL
Description: This command sets current fall slew rate of constant current mode.
Setting Syntax
: [LOAD:]CURR[:LEV][:AMPL][:DC]:FALL
Setting Parameter : <NR1>, 63803/63804 Range: 4~600, 63802 Range: 4~240, Unit:
8-14
Set the RMS current
Set the DC current
:FALL
Set the fall slew rate(DC CC Mode)
:RISE
Set the rise slew rate(DC CC Mode)
Set the maximum RMS current
[:AC]
Set the Irms(max) (AC CR Mode)
:DC
Set the Ip(max) (DC Mode)
[:AMPLitude]
[:AC]
Set the Ip(max) (AC except CR mode)
Return the setting range of current.
0 ~ 18, Unit: A
0 ~ 18, Unit: A
A/msec