Local Operation

3.22 Three Phases Parallel Setting

Each phase in 3-phase parallel mode can connect 5 sets in parallel, and it only can be
operated in CC/CR/CP/RLC/RLC CP modes under AC load. The connection methods of
parallel power include Y and Delta connection which are given as Figure 3-19 and Figure
3-20.
Figure 3-19 Parallel 3-Phase Y connection
3-87