Dc Load Simulation -- Constant Voltage Mode - Chroma 63800 Series Operation & Programming Manual

Programmable ac/dc electronic load
Table of Contents

Advertisement

If there is error during the procedures of inputting value, press CLEAR to
clear the value at any time and then input again.

3.14 DC Load Simulation -- Constant Voltage Mode

In CV mode the Load will sink current to control the voltage source according to
programmed value. User can set the V
CV mode can be entered by pressing the CV key. Enter the voltage and current values with
the keypad.
V s e t = 1 0 0 . 0 0 V
V = 0 . 0 0
I = 0 . 0 0
D C
The procedures of setting V
1. Move the cursor to the command line of "V
V s e t = 1 0 0 . 0 0 V
2. Press 5 , 0 then press ENTER to change the value to "50.00".
V
Voltage setting
Input
Voltage
Load Current
Figure 3-13 Constant Voltage Mode
and I
set
I m a x = 4 5 . 0 0 A
= 50.00, and I
set
max
I m a x = 4 5 . 0 0 A
I
value in this mode.
max
P = 0 . 0 0
= 21.00, are described as below:
=".
set
Local Operation
3-57