Time Measurement; Rlc Measurement - Chroma 63800 Series Operation & Programming Manual

Programmable ac/dc electronic load
Table of Contents

Advertisement

FETCh[:SCALar]:VOLTage:UNDershoot?
Description: Return the undershoot voltage in DC Mode.
Query Syntax
Response Parameter
Example

8.6.2.6 Time Measurement

MEASure | FETCh
[:SCALar]
:TIME
:HOLD
:TRAN
MEASure[:SCALar]:TIME:HOLD?
FETCh[:SCALar]:TIME:HOLD?
Description: Return the measurement value of hold up time (msec)
Query Syntax
Response Parameter
Example
MEASure[:SCALar]:TIME:TRAN?
FETCh[:SCALar]:TIME:TRAN?
Description: Return the measurement value of transfer time (sec)
Query Syntax
Response Parameter
Example

8.6.2.7 RLC Measurement

MEASure | FETCh
[:SCALar]
:RLC
:SET
:CAP
:LS
:RL
:RS
MEASure[:SCALar]:RLC:SET:CAP?
FETCh[:SCALar]:RLC:SET:CAP?
Description: Return the C measurement value of RLC CP mode
Query Syntax
Response Parameter
Example
: MEASure[:SCALar]:VOLTage:UNDershoot?
FETCh[:SCALar]:VOLTage:UNDershoot?
: <NR2>
: MEAS:VOLT:UND?
Return the measurement value of hold up time (msec)
Return the measurement value of transfer time (sec)
: MEASure[:SCALar]:TIME:HOLD?
FETCh[:SCALar]:TIME:HOLD?
: <NR2>
: MEAS:TIME:HOLD?
: MEASure[:SCALar]:TIME:TRAN?
FETCh[:SCALar]:TIME:TRAN?
: <NR2>
: MEAS:TIME:TRAN?
Return the C measurement value of RLC CP mode
Return the Ls measurement value of RLC CP mode
Return the R
measurement value of RLC CP mode
L
Return the Rs measurement value of RLC CP mode
: MEASure[:SCALar]:RLC:SET:CAP?
FETCh[:SCALar]:RLC:SET:CAP?
: <NR2>
: MEASure[:SCALar]:RLC:SET:CAP?
Remote Operation
8-11

Advertisement

Table of Contents
loading

This manual is also suitable for:

638046380263803