3.17.4 CV Mode
Under timing mode to enter CV timing mode press the CV key.
In this mode the loading voltage (V
time and cutoff voltage of the UUT can be set.
V s e t = 1 0 0 . 0 0 V
T I M E O U T = 0 0 : 0 0 : 0 0
V = 0 . 0 0
T
= 0 0 : 0 0 : 0 0 : 0 0 0 m s
H O L D U P
D C
The procedures of setting V
8.5, are described as below:
1. Move the cursor to the command line of "V
V s e t = 2 0 0 . 0 0 V
T I M E O U T = 0 0 : 0 0 : 0 0
2. Press 2 , 0 , 0 then press ENTER to change the value to "200.00".
V s e t = 2 0 0 . 0 0 V
T I M E O U T = 0 0 : 0 0 : 0 0
3. Move the cursor by pressing ( ◄, ► ) to the command line of "I
V s e t = 2 0 0 . 0 0 V
T I M E O U T = 0 0 : 0 0 : 0 0
4. Press 2 , 9 then press ENTER to change the value to "29.0".
V s e t = 2 0 0 . 0 0 V
T I M E O U T = 0 0 : 0 0 : 0 0
5. Move the cursor by pressing ( ◄, ► ) to the command line of "TIMEOUT=00:00:00".
), maximum current value I
set
I m a x = 5 0 . 0 A
C U T O F F
= 200.00, I
(max) = 29.0, Timeout = 00:00:05, and Cutoff V =
set
p
=".
set
(max) , as well as the timeout
p
V = 5 0 . 0 0 0
I p ( m a x ) = 5 0 . 0 A
C U T O F F
V = 5 0 . 0 0 0
I p ( m a x ) = 5 0 . 0 A
C U T O F F
V = 5 0 . 0 0 0
(max)=".
p
I p ( m a x ) = 5 0 . 0 A
C U T O F F
V = 5 0 . 0 0 0
I p ( m a x ) = 2 9 . 0 A
C U T O F F
V = 5 0 . 0 0 0
Local Operation
3-71