R s e t = 1 5 . 0 0 0
T I M E O U T = 0 0 : 0 0 : 1 0
7. Move the cursor by pressing ( ◄, ► ) to the command line of "CUT OFF V=".
R s e t = 1 5 . 0 0 0
T I M E O U T = 0 0 : 0 0 : 1 0
8. Press 3 , 0 then press ENTER to change the value to "30.000".
R s e t = 1 5 . 0 0 0
T I M E O U T = 0 0 : 0 0 : 1 0
9. After setting the parameter of the load, the LOAD ON/OFF key should be pressed to turn
on the load, so that the load can sink the current. (For detailed information please refer
section 3.4.5.)
If there is error during the procedures of inputting value, press CLEAR to
clear the value at any time and then input again.

3.10.3 CP Mode

Once under timing mode, if users want to switch to CP mode of timing mode press CP key
then to enter. There are also have CF ONLY, PF ONLY and BOTH under CP mode for
selection. Its operation methods are the same as CC mode; about the setting method please
refer section 3.10.1.
CP mode page is shown as below. Users can press the arrow key to select the setting
parameters on the LCD display, including power, CF, I
Users can type the values with the Entry keys.
P s e t = 1 0 0 . 0 0
I p ( m a x ) = 5 0 . 0
V = 0 . 0 0
T
= 0 0 : 0 0 : 0 0 : 0 0 0 m s
H O L D U P
A C
C F
O N L Y
I r m s ( m a x ) = 2 5 . 0
C U T O F F
V = 5 0 . 0 0 0
I r m s ( m a x ) = 2 5 . 0
C U T O F F
V = 5 0 . 0 0 0
I r m s ( m a x ) = 2 5 . 0
C U T O F F
V = 3 0 . 0 0 0
(max), Time out and Cut off voltage.
p
C F = 1 . 4 1 4
T I M E O U T = 0 0 : 0 1 : 0 0
C U T O F F
V = 5 0 . 0 0 0
Local Operation
3-45