F947
Input Function Target 1
Program  My Function  My Function Unit 6
This parameter plays a role in the setup of the My Function feature by
selecting the functionality of the programmable Input Function Target 1
terminal.
This setting assigns the function of the programmable Input Function Target 1
terminal to any one of the user-selectable functions listed in
Table 10 on pg.
242, or
Table 12 on pg.
See
F977
for additional information on this parameter.
Input Function Command 1
Program  My Function  My Function Unit 6
This parameter is used to assign a user-selected logical operator to two user-
selected Input Function Target variables, enable a counter/timer function, or
perform a hold/Reset function.
Table 13 on pg. 247
lists the available selections. Their use and selection
requirements are described in an example at F977.
Input Function Target 2
Program  My Function  My Function Unit 6
This parameter plays a role in the setup of the My Function feature by
selecting the functionality of the programmable Input Function Target 2
terminal.
This setting assigns the function of the programmable Input Function Target 2
terminal to any one of the user-selectable functions listed in
Table 10 on pg.
242, or
Table 12 on pg.
See
F977
for additional information on this parameter.
Input Function Command 2
Program  My Function  My Function Unit 6
This parameter is used to assign a user-selected logical operator to two user-
selected Input Function Target variables, enable a counter/timer function, or
perform a hold/Reset function.
Table 13 on pg. 247
lists the available selections. Their use and selection
requirements are described in an example at F977.
Input Function Target 3
Program  My Function  My Function Unit 6
This parameter plays a role in the setup of the My Function feature by
selecting the functionality of the programmable Input Function Target 3
terminal.
This setting assigns the function of the programmable Input Function Target 3
terminal to any one of the user-selectable functions listed in
Table 10 on pg.
242, or
Table 12 on pg.
See
F977
for additional information on this parameter.
220
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Table 9 on pg.
245.
Table 9 on pg.
245.
Table 9 on pg.
245.
ACE-tronics G9 ASD Installation and Operation Manual
Direct Access Number — F947
Parameter Type — Selection List
Factory Default — 0 (Disabled)
Changeable During Run — Yes
241,
Direct Access Number — F948
Parameter Type — Selection List
Factory Default — 0 (NOP)
Direct Access Number — F949
Parameter Type — Selection List
Factory Default — 0 (Disabled)
Changeable During Run — Yes
241,
Direct Access Number — F950
Parameter Type — Selection List
Factory Default — 0 (NOP)
Direct Access Number — F951
Parameter Type — Selection List
Factory Default — 0 (Disabled)
Changeable During Run — Yes
241,
F951

Hide quick links: