F126
Input Terminal 16 (LI8) Function
Program  Terminal  Input Terminals
This parameter is used to set the functionality of the LI8 discrete input terminal.
In addition, this input terminal must be specified as Normally Open or
Normally Closed.
This setting assigns the function of the programmable LI8 terminal to any one
of the user-selectable functions listed in
Note:
The Expansion IO Card Option 2 option board (P/N ETB004Z)
is required to use this terminal.
See the Expansion IO Card Option 2 Instruction Manual (P/N 58686) for
additional information on the function of this terminal.
Output Terminal 1 (OUT1) Function
Program  Terminal  Output Terminals
This parameter is used to set the functionality of the OUT1 discrete output
terminals OUT1-A and OUT1-C.
The OUT1-A to OUT1-C output terminals change states (open or close) as a
function of a user-selected event. See
possible assignments for the OUT1 terminals.
In addition, the output terminals must be specified as Normally Open or
Normally Closed.
Output Terminal 2 (OUT2) Function
Program  Terminal  Output Terminals
This parameter is used to set the functionality of the OUT2 discrete output
terminals OUT2-A and OUT2-C.
The OUT2-A to OUT2-C output terminals change states (open or close) as a
function of a user-selected event. See
possible assignments for the OUT2 terminals.
In addition, the output terminals must be specified as Normally Open or
Normally Closed.
RAKE-A
Output Terminal 3 (BRAKE) Function
RAKE-B
Program  Terminal  Output Terminals
RAKE-C
This parameter is used to set the functionality of the BRAKE output terminals
(A, B, and C) to one of the functions listed in
In addition, the output terminals must be specified as Normally Open or
Normally Closed.
BRAKE Relay is shown in the de-energized state.
96
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Table 7 on pg.
236.
Table 10 on pg. 242
for listing the
Table 10 on pg. 242
for listing the
Table 10 on pg.
242.
Direct Access Number — F126
Parameter Type — Selection List
Factory Default — Unassigned
Changeable During Run — No
Direct Access Number — F130
Parameter Type — Selection List
Factory Default — Brake Failure
Changeable During Run — No
Direct Access Number — F131
Parameter Type — Selection List
Factory Default — Brake Release
Changeable During Run — No
Direct Access Number — F132
Parameter Type — Selection List
Factory Default — Brake Release
Changeable During Run — No
ACE-tronics G9 ASD Installation and Operation Manual
F132

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents